A structured summary for distributors, OEM buyers and technical teams reviewing sodium-ion battery fit before sample validation.
A sodium-ion start-stop battery platform for frequent cranking and urban duty.
NaVolt H-series batteries are built for automatic start-stop vehicles, light fleets and cold-region replacement programs that need high-pulse starting, frequent charge-discharge tolerance and stable PACK-level protection. The platform is positioned as an AGM/EFB replacement path for buyers reviewing lower lifetime maintenance pressure and stronger low-temperature behavior.
Chemistry
Sodium-ion
Protection
IP67
Charge Voltage
15.8 V
Discharge Cut-Off
6 V
02
Technical Specifications
Core parameters are presented first so procurement, engineering and project teams can quickly judge electrical fit, installation space and quotation readiness.
Chemistry
Sodium-ion
Nominal voltage
12 V
Voltage range
6-15.8 V
Charge voltage
15.8 V
Discharge cut-off
6 V
Charge temperature
-20C to 45C
Discharge temperature
-45C to 60C
Storage temperature
0C to 45C
Protection
IP67
Start-stop cycles
>100,000
Cycle life
>3,000
Interface
Positive and negative terminals, M6 bolt type
Capacity
80 Ah +/- 5%
CCA
1600 A
Max size
410 x 175 x 190 mm
Weight
11.40 +/- 0.5 kg
Continuous discharge
<= 80 A
Continuous charge
<= 40 A
Internal resistance
<= 4 mOhm
03
Product Applications
Recommended for vehicles or fleets where frequent start-stop cycling, short-trip recharge pressure and winter starting reliability are key buying factors.
Large displacement vehicles
Diesel applications
Fleet maintenance programs
04
Features and Advantages
Beyond nominal parameters, buyers need confidence in cold starts, cycle behavior, safety, export preparation and service support.
Cold-start ready positioning
Sodium-ion chemistry is positioned for severe low-temperature starting review, with supplied business material highlighting normal use across cold and hot climates.
High-pulse cranking output
H9-12V-900 provides 1600 A CCA for engine starting review, helping buyers compare output against original battery size and vehicle demand.
NaVolt can support product selection, sample validation, datasheet review, packaging notes and required export documentation discussions for partner programs.
05
Service and Project Support
Share your voltage, capacity, installation space, target market and expected order plan. NaVolt helps match the product, documents and cooperation path.
Model matching by voltage, CCA, capacity and battery size
Private label and packaging support for partner programs
Sample validation, inspection and aging test communication
Datasheets, company profile and export document coordination
What is the H9-12V-900 sodium-ion battery used for?
H9-12V-900 Sodium-ion Start-Stop Battery is a sodium-ion start-stop battery designed for Large displacement vehicles, Diesel applications, Fleet maintenance programs. It helps distributors, OEM buyers and fleet service teams review 12 V voltage, 80 Ah +/- 5% capacity and 1600 A CCA before sample validation or bulk quotation.
Can H9-12V-900 replace a traditional lead-acid battery?
H9-12V-900 is positioned for AGM/EFB lead-acid start-stop battery replacement projects where buyers need sodium-ion battery performance, practical case-size matching and export-ready technical support. Final matching should be confirmed by battery tray size, terminal layout, cranking current, vehicle load and local installation requirements.
Why choose a sodium-ion starter battery instead of a lead-acid battery?
NaVolt sodium-ion starter and start-stop batteries are designed for high-pulse cranking, low-temperature starting review, lower self-discharge positioning and lighter PACK options than many lead-acid alternatives. This makes the platform suitable for automotive aftermarket distributors, fleet replacement programs and OEM/ODM battery projects.
What specifications should I confirm before ordering H9-12V-900?
Key items include nominal voltage 12 V, capacity 80 Ah +/- 5%, CCA 1600 A, dimensions 410 x 175 x 190 mm, weight 11.40 +/- 0.5 kg, terminal type Review datasheet, charge voltage 15.8 V and discharge cut-off 6 V. Sharing the original battery model and target application helps NaVolt recommend the correct sodium-ion battery model.
Is this battery suitable for cold-region vehicle starting?
H9-12V-900 is part of NaVolt's sodium-ion battery range for cold-start reliability review. The listed temperature data includes charging temperature -20C to 45C and discharging temperature -45C to 60C, while supplied business materials position NaVolt sodium-ion starter batteries for severe winter routes and cold-region replacement markets.
Can NaVolt support OEM, ODM or distributor battery projects?
Yes. NaVolt supports B2B sodium-ion battery buyers with model selection, private label and packaging communication, datasheet review, sample validation, export document coordination and project quotation support for automotive, fleet, marine, machinery and specialty starting applications.
No matching content yet. Try product model, application name, CCA, AGM, truck, marine, FAQ or downloads.